Hi Shannon, the bolts are spinning. Went out today to find the lower plastic shroud melting again? Hayward pumps use different shaft seals, you can find the correct one here: https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG . No matter what setting I put it in its backwashing the sand into the skimmer. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. If its not the cord, I would suggest the filter, cleaning the fingers with a good soak to de-scale and de-grease. When this has been corrected, shut the power down to the pump and rest it after 15 minutes. I have my pump to run each evening from 10:30pm to 9:30am. Hi, it could be the filter, and if so, the pressure on the gauge would be high during operation usually. Hi Bobby, so you have power at the motor, but no noise. Step 1: With your pump running, double-check the positions of your valves. Replacement of the gasket inside the valve is the fix. Lube should not be the issue with the leak, not required. Troubleshooting Guides; Troubleshooting Guides. Dear Davy, my pump was working two days ago then I switched it off. or if i let it rest for like 10 to 15 min it will start right up on its own when i hit the switch. Hi Jim, sounds like an air leak, or low water in the pool, or a stuck skimmer weir blocking water flow into the skimmer. Probably a loose fitting, clamp or o-ring. I used the override switch and it fired up and left it on for several hours then turned it over to auto and it worked again but has since stopped. Thanks. Within the underground world of Japan, and the world at large, a certain man is known as the Evil Emperor. I have a six year old Hayward sp3400vsp and theyre recommending I replace it with the pen take intelliflo. The new pump then starts to overheat and it shuts off. Also installed a brand new circuit box to allow for the bigger pump its a 20A GFCI breaker with 12 gauge wire going to the pump. Sir, I have a Hayward Ecostar 3400 variable speed pump and will not run anymore. The pump does not start. Breakers and outlets do go bad after many years, usually last over 20 yrs, but can fail sooner. I checked pool water supply and dont feel any water coming but my pump is still running but nothing is moving in pool. Thanks a lot! I was wondering if the Hayward Cyclac Ball Value could be leaking? I have the intermatic digital two speed timer. Please help! There is not much that can be done to increase flow rates for a smaller pump, with exception to reducing plumbing restrictions with larger pipe size and less elbows, etc. Sometimes it is just a stick or debris stuck between the valve diverter (aka rotor or footpad) and the spider gasket, and a little wiggle or jiggle or repositioning of the handle can seal up the waste port, for a time If it reoccurs, this means that the spider gasket is twisted, worn or damaged. There may be some stray voltage running around the system, on the bonding wire. Any advise on what is the problem? If valve is open when it should be closed the heater will shut down and go into lockout. Hi William, yes an air leak, is what I call it. Are you getting 230V (207v 253V) at the pump? FYI I moved the voltage selector to 115. I just purchased a new pump for my pool. If a LED is ON, check to see if the flow switch was installed correctly. Third guess is closed or broken valves, clogged filter, clogged impeller, or other obstruction preventing water flow. If it is not, re-align your flow switch. I have a hayward superpump and upon starting the pump, it sucks the water into the pump basket but when it is filled with water the pump will start revving up and down. Check all connections, circuit breakers, and fuses. Don't stress! I then tried the pump at various speeds and it did not prime and circulate the water through the pool. ), it could be a bad breaker, they can fail or become too sensitive with age. I have a Hayward E40, After I vacuum the pool I see that I have D.E on the bottom again after two days or so. "description": "Hayward Pool Heater Troubleshooting Guide - how to step by step approach to determining if the water supply, gas supply, electrical supply or a component of the heater is causing the issue. Hello, Im having an issue where my variable speed pump is pushing de back into the pool however it only does this when its running at a lower RPM and does not exhibit this issue when running at priming speed or a higher RPM. You must log in or register to reply here. But lack of sand should not cause a leaking problem. Is this the problem and should I get i checked or just replace it? Replaced breaker still nothing. The instant salinity in both polarities should be about the same (+/- about 200 ppm). But heaters? Any suggestions welcome. The pump is pretty hot. I have a Hayward Ultra Pro LX pump. Hello, I have a H200 natural gas heater . You need to use a K-1766 salt test kit or a calibrated meter. I had to have a pool person come out & they got me good. Step 2: Verify the accuracy of the salt readings (2700-3400 pm) with an independent test kit or by taking a water sample to your local pool store for testing. Hi Dave, check the owners manual to be sure that the cord size used is proper for the motor, and the plug, is a 3-prong grounded plug? that is quite unusual, the 3/4 hp Super II is designed to pull much less, probably around 12 amps. The correct lateral assy for the S210 filter would be the SX210DA if you used a smaller assy, the pipe wont reach all the way into (inside of) the multiport valve base, and allow sand to enter the pipe but just a theory, you likely used the correct and full height SX210DA? My Hayward pump is only about 3 yrs old. please help. "height": "219",
Hi Carrie, sounds like an air leak, which is air being sucked into the pump, from somewhere in Front of the impeller, News Reporter Reveals On Live TV That Shes Been Secretly Recording Dec 14, 2021. 1. Be sure that all pool valves are open and any wall plugs are removed before turning on pump. Gail, good luck! Flow switches require a minimum flow fate of 11 gallons per minute to stay consistently closed, Water temperature is below 50 degrees F. (The cell output scales back to 20% once it reaches 60 degrees F and shuts off at 50 degrees F.). Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. Check for power with a multimeter, at the timeclock and at the pump motor terminal board. What can I do? Its half as light as say, flour so we use twice as much. Loud screeching sound from 2 speed 1 HP pump, louder on faster speed. If your pump is made of plastic, it must be the bearings, failing so hard that it is causing the motor to overheat. I opened the back and was spinning the rod and it eventually started. "author": {
If so, you may try to glue them in place with JB Weld or similar, and if that doesnt work, a new housing would be in order. Good luck! Might be some voltage issues? You could take the motor or pump into an electrical motor shop for confirmation. After trying every chemical under the sun and replacing the sand, I pulled the trigger and started from scratch. I dont know if Im convinced the new pump is bad or not, or if I need higher voltage to the pump. The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing We would like to show you a description here but the site wont allow us. The most likely is an air leak, and the usual places are 1) pump lid not tight enough or not lubed, or bad o-ring, or loose drain plugs (or without thread sealant or o-ring). 2. It feels like its not doing what its supposed to do. "name": "In The Swim",
Not all horsepowers are created equal, meaning that a 1hp Hayward Super II pumps a lot more water than a 1hp Hayward Super I, or Max-Flo. Royal Tulip Beach Resort is located near Port Ghalib, 42 km from Marsa Alam. Any insight would be helpful. Quite a criticism for something costing 33bn-plus. Weve not had this issue the past 2 years (we bought the house 2 years ago). larger hp motors, are not reversible. "width": "611",
dual-speed pool pump. My salt water pool was shut down for the winter. Hola Ral, Podra ser una de 4 cosas: encendedor, sensor de fuego, baja presin de gas o el tablero de control. 5. YOu can shim under a piece of rubber, or carpet, or cardboard which wont last long, but anything between the pump and the pad should quiet the pump, and take up space to prevent the vibration. v when it is turned to 230v and re wired for 220-230 v it makes no noise at all. I checked the pump and is is very hot. 2. Could be a short in the wiring that could be tested with an Ohm meter, for resistance. You can also turn off the pump at the breaker which provides power to the timer. New gauge was ordered. How To Fix The Problem If you havent inspected your cell yet, now is aperfect time. It is brand new. We only use the pump in the summer months, since we live in Canada. 5. very dirty pool filter, Every time the pump is turned on with the timer it trips the circuit breaker. The breakers still seem to be working since when I turn the breaker on and the timer switch for the pump, it does send power to the pump. "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-heater-troubleshooting/",
Works great minus the vacuum created is so great that getting the lid off of the basket is so great a breaker bar is needed to remove it. Also, using Teflon pool lube on the pump lid oring should help. Hi Brian, is this a DE filter? Any ideas how to address this? Thanks. Thank you I have taken the thing apart several times and cleaned those fingers but that wasnt the problem this timeI took a chance and tried the vacuum to see if any debris actually made it to the filter basket and nothing went throughso got a plunger and forced the water through with that and then the pump finally primed!! Hi, that could be many things, from low water level to a broken impeller, but its usually an air leak. The motor on my Hayward super pump 2 went out so I ordered a Hayward replacement. . If you have an intermatic clock (big yellow dial), there are a series of gears behind the dial, that all need to be engaged. If the shaft is free turning, but the pump does not turn on, check power connections. If your sweeper has a booster pump, could be a problem with a clogged impeller, or air leak into the pump, or some other pump issue. The pump is working great but concerned about the hot cord. "width": "611",
Hi Leah, good question, and I understand. Could possibly be loose wires on the motor or timer, possibly a loose centrifugal switch or stationary switch on the motor, or maybe the windings in the motor are shorting out. Capacitors are cheap to replace, or you can test the capacitor Motor will hum for a few seconds and eventually trip the breaker. Is it plug and play? If the cell is still producing chlorine, it should be fine. Whenever Ive seen that its from too much voltage, like connecting 220V to a motor wired for 110V. If you download the owners manual on the Ecostar there is some further information about Drive Errors, and some things you can try, in the troubleshooting section, to verify the fault, and also lists the part number for the drive, if needed. The pump starts up fine and draws water but then it starts clicking as if its shutting off and on. Upon restart, pump sounds horrible, like pumping rocks. But, you probably just need a $15 shaft seal, which is not overly difficult to replace. The Aqua Rite runs at maximum out for for the remainder of the current pump cycle or for 24 hours, whichever comes first. Don, melted shrouds can indicate that the something may be laying on the burner tray, causing flames to shoot out a little sideways, or something is laying on (or clogging) the heat exchanger, allowing hot gas to build up inside the heater, slowing down the exhaust rate. If thats not the problem, try soaking the fingers again, with a stronger solution, and/or leaving them soaking longer. This new one when turned on seems to start, and pump, but the breaker shuts off in probably less than a second. This quick spray of water when you shut the pump off, as you have experienced, are a useful tool in locating an air leak on a pump. Hi Wade, check the switches in the rear of the motor, the stationary switch, located at 6 oclock, and the centrifugal switch, located dead center. But most aboveground pool pumps are 115V, and certainly is if it came with the cord. I presume Ill be looking at buying a new pump next year. After reinstalling, give it the full charge of DE powder, plus a little extra. . The low speed works fine. Do I need to use lube on the gasket, how much sand should be in the filter? Its concerning to suddenly hear strange sounds coming from your Hayward pool pump. Cant find anything that jumps right out. Also check that the wires on the front, from breaker and to pump, are tightly secured, and no burn marks. Also will need to have clean pump basket and a clean pool filter, to ensure adequate flow rates. Lube Gasket (after cleaning, with a rag lube with Teflon or Silicone based pool lube) and 3. After we run the pump for a few minutes and then take the pump apart there is water in the impeller- but the water is where the seat housing is. Any insight? it continues to cycle this way. I changed the sand and it is still occurring. I calibrated the unit to 3100 ppm. My salt was tested today at 3000 and everything else was perfect. As you found, if the motor sounds just as loud when it is pulled out or removed from the pump housing its usually the bearings, which normally last for up to 10 years, not in this case it seems. If it does not, keep reading. I have a maxi-flo 2 and it just stopped working. What is the problem. Contains 13 high-performance titanium electrode plates that are coated with a special formula that combines the most corrosion-resistant metal on earth, iridium and ruthenium, to ensure extended cell life and increased chlorine production efficiency. The cell amperage is above the maximum limit. Any help,appreciated. I have water coming out the side of the sand filter where u would back wash? Hi Tony, yes if the impeller spins freely then the shaft does too (unless you are unthreading the impeller from a stationary shaft) normally. Not the 12VAC that it says should be there. my hayward filter assembly on top leaks at the seam between the top (held on by six bolts) and the bottom. JUst installed new heyward pump . If one of the keypad buttons is closed (or pressed) for more than 30 s the error code will be displayed but the control will continue to function. Shut off power at the breaker to all pool equipment 4 New pump 2 years old. I have a new above ground pool with a Hayword pump. My pump seems to be working fine but Im having an issue with the flow pulsating out of the filter. If so, shut off power and see if the motor shaft will spin. Holding the shaft stationary (so it wont turn), unthread the impeller, counter clockwise, to remove. Check the wiring in the back of the motor, is the cord firmly attached? See if your test button has popped out on the outlet, or perhaps you have one on the breaker, a test/reset button. Put things back together and still have error. I have a 2 HP Hayward two speed pump that is on its second season. My check salt generator station even after I clean it out. I owe you a beer if you are ever around my neck of the woods. I went out Toto shut it off so I could backwash and add chlorine. it does not turn on even though i get 240 volts.My blower is on a different circuit and works properly with 240 volts. You will need a new plug and a new outlet and maybe a new pump too (? Gasket Maker. Hi Joe, I would first suspect an air leak, Superpumps can also draw air from a loose drain plug and easily around the square lid gasket but the usual suspect is the pipe coming into the pump. If pressure is lower than normal check for air leak on the suction side of the pump, or a clogged impeller, or low water level, stuck skimmer weir, or closed suction valves. At75%, or lower, in either polarity, it's time to consider replacing the cell. If the pump runs without water for very long it will burn up the shaft seal, and if run for hours and days, can literally melt the pump, sometimes even catch fire (rarely), even with a small amount of water in it. I would test the voltage at the motor terminal board, very quickly, before the breaker trips, to be sure its between 210V-250V coming in. There is water under the motor not sure from where. Learn more about pool care and repair. Good morning. Reset AquaRite Salt Chlorination Inspect Cell Light If the Inspect Cell Light is the only LED light flashing, then you can reset it by simply holding down the diagnostic button for 3 seconds, then release. if the motor is generating too much heat, this temp sensor will trip and shut off the pump. 2. loose pipe coming into pump, drawing air around fitting threads We had a pool built in FL in Aug 2018 with variable speed Hayward TriStar pump. Any idea what the problem could be? I have been getting GFI breaker trips intermittently. Products, Learn About In the meantime, could you send me a link for the capacitor that I need? IF the shaft does spin freely, yet the breaker trips, check the wiring for wires touching each other or the motor housing, loose wires, broken wires or corroded wires or water in the conduit, surrounding broken wires. The pump acts like it wants to pump, but doesnt. Still have Drive error, heatsync overheated and day of weekflashing back and forth between the two. Automatic reset is immediate after the switch closes, Blower vacuum switch open when expected closed error. If you suspect your breaker has broken, call a certified electrician to further diagnose the problem. Similar pumps, with the same flow rate characteristics, are not less expensive. Replace the seal in the same orientation as you removed it, and reassemble. that is correct, those are the usual suspects. Loose connection inside the plug or socket. If I leave it plugged in then it stays hot, but if I unplug it then it cools off and itll work till it overheats again. 14 x 28 inground, water clear. If you have a multiport valve, set it on Recirculate, to bypass the filter, and rule out any problems there. Next year, June 21, 2021, is the date that VS (Variable Speed) pumps will be required, over 1-hp in size. Good that you have the waterfall pump, that will help tremendously. Interesting enough, if I place it in super chlorinate mode, it will produce chorine. I dont see any leaks n pressure seems little bit higher than normal. Grass clippings, seeds, gravel or other small debris can clog an impeller and reduce suction. Perflex filters can also leak out of the bump handle, this fix usually involves replacing the shaft o-rings. You might be surprised by how many people neglect to check this area. Before you test your capacitor, take note of its appearance. As soon as I hook it up and it starts pumping water the pump slows down and struggles, the sound is very noticeable. Next, check continuity from lead to lead. Any idea how to fix this? The shaft turned with zero resistance. We have Hayward Perflex filter parts here: https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG. Hi Jack, according to the manual, the Drive Error Pump is Stalled error usually refers to water or moisture on the circuit board, under the display panel. I was attempting to replace shaft seals when something went wrong. Hi, my Hayward super pump is thermo protected. I would guess this is what is happening, and if so your service company is either uneducated or dishonest. "publisher": {
I put new sand it its still dumping could it have been sand still in the line what you think or is there anything else that could cause this I put 200 lbs of sand in which is the correct amount . You can remove the cartridge, reassemble the filter and run the system, just to verify that the cartridge is the problem. I took the lid of the pump basket and cleaned the seal and placed it back on tightly, but there are small bubbles still coming out of the pool jets. Hi, when my Hayward pool heater is on Im getting a sour odour from the exhaust. Pump making loud grinding noise, any solutions. Second possibility is the pump is too high above water level. Also, if there is a GFCI outlet connected, perhaps it is tripped? "@type": "Person",
Baal School; Skill Training for Girls This year, I have replaced all the plumbing from the pump to the filer. Even the power light is not on. that would be rare, very rare. You can check the visual motor check (if you have an intermatic clock), to see if the motor gears are turning, which means the timeclock motor is good and the power from the breaker is good. After removing the capicitor and the thermal load, we were able to get a 7/16 wrench on the shaft at around 12 oclock, but the shaft only has two flat sides and we are only able to move the shaft like 1/12th of a revolution clockwise and counter-clockwise (back and forth between 11 and 12 oclock). My pool suppoier said 50lb but the info on the description of the filter on the site where purchased says 100 lbs. Thanks Davy for your quick reply. But after that, you should be able to override any programs with the buttons. Ive tried the override, checked the basket on the pump and felt into the intake and outlet for obstructions. i cleaned the filter put the cover back on turned the pump but it doesnt seem to be priming . Hi David, spilling water on the motor is no problem, they do fine outside in the rain (flooding is a different story) Have you checked the GFCI test button on the outlet? Seal up the air leak in the front of the pump, then bleed off all the air in the filter tank, and the bubbling should cease. The pump is 18 yrs. A common mistake is to install the spring seal half backwards. Just replaced the sand and cleaned the fingers, replaced the o rings and have a psi of 15 and great suction. At the end of last year, I had a leak in the diverter valve. The capacitor is at 9 oclock and the thermal regulator at 12 oclock. To fix the problem, manually reset the Inspect Cell LED. Hope thats not the case. Usually OK with a 12 lift, but more than that can be a struggle. Currently it is at pool level. The breaker on the panel tripped. The motor can be tested briefly without being bolted onto the pump. Sometimes I need to backwash and rinse before the water seems to get going enough to actually circulate, then Im able to switch to filter and it works. Inspect the circuit board, blow off with some air, and look closely at the 3 wires for any insects, spiderwebs or corrosion of any type. "@context": "https://schema.org/",
Hi Mary, flocculents usually produce a fluffy precipitate that is vacuumed to waste, because it clogs ups the filter. And 93, thats just the temp of the water, the flames are much hotter of course, thats what is melting the plastic. Hi Jodi, perhaps the rod is not threaded all the way into the base, or there may be debris under the rod, preventing it from going down fully. Sometimes you can pull out the clog with needle nose pliers. Outlet works fine. We have a Hayward 1.5 lx. Check the incoming motor voltage to be sure it is correct, too low or too high can cause problems. Bobby, yes that would rule out the power source, or the outlet as being the problem. I would like to repair it if possible. Hi Deb, probably a bad outlet or a bad cord, or a loose connection on one or both of those. No pressure now. Morning , everything was working fine with my Hayward pump. If you program an incorrect cell size, the salt level, amperage, and voltage will not be correct and the system will turn off. It is quite rare that while testing a capacitor, it explodes (small explosion), but it can happen. Yours may have become weak, or damaged somehow. If all good, check the capacitor, at 9 oclock, looking for bulging or cracking or burned marks. Fault with the pump wiring. When turned on, it clicks in and off every few seconds. Likewise, check if the motor is wired correctly for the available field supply voltage. 2017). The loud noise could be the bearings, or it could be the impeller having come off the shaft and contacting the volute if you have an older bronze or brass pump, with an impeller that uses a stub shaft. Hi Terri, when you connect the vacuum hose to the skimmer to start vacuuming, this is like increasing the length of the pipe from the pool to the pump, which makes the pump have to work harder, kind of like drinking through a very long straw. You may be able to remove the basket and reach thru the volute to the eye of the impeller, and may be able to feel debris. If you can, you can check voltage with a meter, on the breaker, to see how much voltage it is passing. First time pool owner (obviously dont know what we are doing). After about 15minutes the pump stopped and the motor was super hot. The salt cylinder is clean. I didnt plug the line and got a lot of water on the pump motor. The issue continue to happen so I called a pool repair technician and he came out and verified that the filter was put together properly and also replaced the O-rings in the backwash valve. Our Hayward pump is leaking and we just added our opening chemicals. It could be a problem the other way around, AG pumps cannot lift water vertically, so are not used on inground pools. 25 LibriVox About. Hope that helps! It now trips the breaker whenever i try to turn it back on. Hello, I have a 2 yo, dual speed Hayward Super Pump (same as the one you have pictured above). A lb of DE is by volume, equal to a 1 lb coffee can, or about 4 cups of dry measure. Salt cells create cloudy bubbles, Ozonators too. dont know if the pump went bad already. Flip circuit breaker all the way Off, then back on again. Just started getting a No Flow error. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. I would recommend getting a plug-in timeclock so you dont need to plug/unplug it all the time. pool water analysis near me; camel leather reclining sectional; chiaogoo twist shorties set; 24 emsco resin hydro pickers garden system; pool cover 16x10 oval; Hi Clara click doesnt sound like a motor runnning, perhaps you are hearing a relay click, but if the motor itself is not turning over there could be a multitude of reasons why, but in most of these cases, the problem lies where the power dies. Do you know what the suggested torque is for the housing cap screws? Hi, We had a pool installed last fall and we are still figuring things out. Hi, I have a H250PED2. Hi Douglas, it could be the capacitor, if youre lucky. I even tried another new housing gasket and it still leaks. If it is a 15amp breaker, but the pump wants 9amps and the aquatrol wants 7 amps, (for example, made-up numbers) thats a total of 16amps, too much. All Im being advised by an electrician that my Hayward pump has a dead short in it. Step 2: Did you properly install your switch? I first thought it might be the motor capacitor, new cap, problem still the same. Every time I vacuum my pool and then back wash and rinse. Ryan, is the breaker a 15-amp? Nothing your husband did, hes safe to come out of the doghouse, lol. Below is a list of common issues that can arise with your Hayward pool heater. You can also call Hayward directly for tech support. Also look for any burn marks on the wire terminal board, or any crimped wires running round the rear of the motor. Our switch seems to be getting power- a voltage tester confirms this but pump makes zero sound when switch is turned on.